intecexpo.com

What Is Abend U4038?

FAQs Jackson Bowman July 23, 2022

A U4038 evening is a user evening coming from Language Environment, the “runtime” for mainframe programs (it supports several mainframe languages). You have more information about this.

What is user abend code 4038?

In this particular case, the abend 4038 is due to the COBOL application dynamically calling an unavailable module; This could be because the wrong module name was specified in the CALL, or the module may not exist.

What is the reason for the abend message a file open error?

Possible causes:

Trying to open an open file. There was a conflict between the program, the JCL DCB, and the dataset DCB information. An incorrect block or record length was specified. An attempt was made to write to an input record.

What is an abend code?

ABEND code U-0013 or U0013 (X’000D’) is issued when a failure or error condition occurs in which normal program execution cannot continue. An associated reason code (which is normally contained in general register 15 at the time of the ABEND) further describes the condition.

What is abend U4087?

U4087 (X’FF7′)

A recursive error was detected. A condition was triggered, causing the number of nested conditions to exceed the limit specified by the DEPTHCONDLMT option. The reason code indicates which subcomponent or process was running when the exception was detected.

How do you resolve u4038?

PROCESS DEPARTMENT. DISPLAY “START PROGRAM..” PERFORM INITIALIZATION PERFORM EXIT GOBACK. INITIALIZATION. DISPLAY “OPENING FILE..” OPEN INPUT INFILE IF WS-FILE-STATUS NOT EQUAL TO ’00’ THEN GO TO ERROR-EXIT END-IF.

How do you resolve in soc4?

How to solve S0C4? You can check if the program contains uninitialized indexes or indexes. You can check if the program is reading an unopened file. You can verify that the LRECL matches the file length specified in the file descriptor in COBOL.

What is abend mainframe?

The term evening is more common on older mainframe systems than on PCs and typically refers to the abnormal end of an application rather than an operating system glitch. Operating system failure is more commonly referred to as a crash.

What is the use of the abend command?

Description. HANDLE ABEND handles an abnormal termination exit. This command is used to enable, cancel, or re-enable an exit for abnormal termination processing.

How do you check abend in mainframe?

If you have ABENDAIDs in your JCL, you can see detailed information about your evening there. //SYSDUMP DD SYSOUT=* in your job, it provides the dump for the abort step.

What is abend S002?

S002. This abort can result from the following: – For SORTOUT or OUTFIL records with variable length records, the. Record descriptor word was invalid (less than 4 bytes or greater. than 32 KB) or was greater than.

for non-spanned records

What is S322 abend in JCL?

On a mainframe, a job aborts with an S322 abort code if the TIME value per job or per step has been exceeded.

What is U0016 abend in JCL?

Message DSO501 often appears with abend U0016. The most common reason for termination is improper concatenation of extractor data. An error condition occurs when multiple records with the same name are detected on a single volume.

What is S04E Abend?

S04E error means a duplicate utility ID was created. If your job aborts while running, it creates a duplicate utility ID. If you resubmit the same job without ending the duplicate utility id, you will get a so4e error. You can exit this utility ID in two ways.

What is Region parameter in JCL?

The

JCL-REGION parameter is an optional keyword parameter and you can define the REGION parameter at either the JOB level or the STEP level, or both. If you define the JCL REGION parameter at the job level, then this is the amount of virtual memory that a job requires to run.

How do you resolve s878 Abend?

References:

  1. https://www.ibm.com/support/pages/4038-or-4087-and-handle-abend-routine-does-not-gain-control-cics-ts
  2. https://ibmmainframes.com/references/a29.html
  3. https://www.ibm.com/docs/SSQHWE_10.5.0/com.ibm.ondemand.administeringzos.doc/doday016.htm
  4. https://www.ibm.com/docs/SSLTBW_2.2.0/com.ibm.zos.v2r2.ceea900/cs00015.htm
  5. https://stackoverflow.com/questions/33304402/how-to-fix-a-u4038-in-a-simple-program
  6. https://www.facebook.com/325846324733749/posts/a-s0c4-abends0c4-abend-is-a-protection-exception-when-a-virtual-address-cannot-b/393603877957993/
  7. https://www.techtarget.com/searchdatacenter/definition/abend
  8. https://www.ibm.com/docs/SSAL2T_8.2.0/com.ibm.cics.tx.doc/reference/r_handle_abend.html
  9. https://ibmmainframes.com/about25095.html
  10. https://mainframesf1.com/tag/s002/
  11. https://www.microfocus.com/documentation/enterprise-developer/ed60/ES-WIN/BKCBCBWJTOS003.html
  12. https://docs.bmc.com/docs/messages/messages-u1-through-u9999-cmf-monitor-718476153.html
  13. https://ibmmainframes.com/about5878.html
  14. https://www.tutorialbrain.com/mainframe/jcl_region_parameter/
  15. https://www.ibm.com/support/pages/abend-s878-reason-code-10-and-u4087-abend

© 2022 intecexpo.com

We use cookies to ensure that we give you the best experience on our website.
Privacy Policy